contrⒶLS · Bi-Level · Occupancy sensor
MSM-SDI/54P1 /BLS
High-bay microwave sensor for lamparⒶRCH · 1-pin
Microwave occupancy sensor made for lamparⒶRCH high bays. Plugs into the 1-pin audio-jack port and mounts up to 40 ft. Hold time, sensitivity, stand-by level and daylight harvesting (10–2,000 lux) are set with the IR remote from the floor, with a walk-through test mode. Standalone: no network, no app.
Sensor
OCCUPIED
Light level
100%
Hold
—
Stand-by shown at the 10% floor of the 10–100% range.
Downloads
Documents & tools
Documents
Tools & support
Model specifications
MSM-SDI/54P1/BLS
Performance
| Detection | Microwave · 5.8 GHz |
|---|---|
| Max mounting height | 40 ft (12 m) |
| Detection range | Adjustable · IR remote |
| Hold time | 5 s – 30 min |
| Stand-by dimming | 10 – 100% |
| Daylight harvesting | Yes · 10–2,000 lux |
Electrical
| Input voltage | 10–15 Vdc |
|---|---|
| Connector | 1-pin audio jack |
Installation
| Commissioning | IR remote |
|---|---|
| Network | None · standalone |
Construction
| Rating | IP20 |
|---|---|
| Operating temp | −4 °F to 122 °F (−20 °C to 50 °C) |
| Finish | White |
Compliance
| Certification | UL Listed |
|---|---|
| DLC NLC | No · standalone sensor |
| Warranty | — |
How it works
One sensor, one luminaire. Nothing to network.
Occupied
Full output on motion
The sensor sees movement and the fixture runs at full output.
Vacant
Hold time, then stand-by
After the hold time (5 s – 30 min) the light drops to its stand-by level instead of switching off.
Daylight
Holds back when it's bright
The built-in daylight sensor keeps the fixture from running when there is enough daylight.
Set-up
IR remote, from the floor
Hold time, sensitivity, stand-by level and daylight threshold are set with the RM-SD/100S remote. Walk-through test mode included.
Detection
Rated to 40 ft.
Mounting · side elevation, to scale40 ft max
Adjustable on sitestandalone
Hold time
5 s – 30 minSet with the remote.
Stand-by level
10 – 100 %Where the light rests when the space is empty.
Detection range
IR adj.Adjustable with the IR remote. Pattern not dimensioned on the datasheet.
Daylight
10–2,000Lux. Built-in daylight harvesting sensor.
Connector
1-pin audio jack
Plugs into the lamparⒶRCH 1-pin sensor port.
Where it fits
Luminaires that take this sensor
Compatible remote
RM-SD/100S
S Series IR remote
Platforms
Same plug-in idea, three ways to run it.
Bi-Level
Standalone
- Network
- None · standalone
- Set up with
- IR remote, dials or DIP
- Scale
- One fixture
- Input
- 10–15 Vdc · or line voltage
- Reporting
- —
- DLC NLC
- No · standalone
by ⒶCS
Mesh + cloud
- Network
- Wireless mesh
- Set up with
- ⒶCS app · QR code
- Scale
- Up to 500 nodes
- Input
- 12–24 Vdc · or line voltage
- Reporting
- Cloud dashboard · rebate export
- DLC NLC
- Listed · V5.2
Nearest ⒶCS fixture sensor
MSP-SRI/903P1/ACSby SILVAIR
Enterprise NLC
- Network
- Wireless mesh · SILVAIR
- Set up with
- SILVAIR app
- Scale
- 500+ nodes
- Input
- 12–24 Vdc
- Reporting
- BMS via open APIs
- DLC NLC
- Listed · V5.2
Nearest SILVAIR high-mount microwave
MSM-SRI/903P1/NLCOrder
Read the catalog number
MSM
Microwave sensor
SDI
Indoor
54P1
Series 54 · 1-pin
/BLS
Bi-Level
Ordering information
At a glance
| Catalog number | MSM-SDI/54P1/BLS |
|---|---|
| UPC | 819313023527 |
| Listing | UL Listed |
| DLC | Not applicable · standalone |
| Warranty | — |
| Brand | contrⒶLS |
| Platform | Bi-Level |
| Manufacturer | Archipelago Lighting Group |
Not sure which platform?
Standalone, mesh or enterprise.
Start from the job: one fixture that dims itself, a building you want to see and report on, or a network that talks to the BMS.
Rebates
Check rebates before you specify.
Utility programs for lighting controls vary by service territory. The Rebate Center shows what applies to your site.