contrⒶLS · by ⒶCS · Occupancy sensor

MSP-SRI/903P1/ACS

Fixture-integrated PIR sensor · 1-pin audio jack · wireless mesh

PIR occupancy sensor that plugs into the 1-pin audio-jack port on ⒶRCH luminaires, at the factory or in the field. Powered by the fixture's own driver. Joins an ⒶCS mesh of up to 500 nodes and commissions from the ⒶCS app by QR code: no gateway, no IT, no on-site Wi-Fi. If the cloud is unreachable, occupancy, daylight and schedules keep running.

13ftMax mount
12–24VdcHost driver
500nodesPer mesh
<0.5WTypical
UL · FCC · RoHSIP20DLC NLC Listed · V5.2
MSP-SRI/903P1/ACS occupancy sensor

Sensor

OCCUPIED

Light level

100%

Hold

—

Hold time and stand-by are set in the ⒶCS app; the bar is illustrative.

Downloads

Documents & tools

Documents

Some documents for this model are held for re-issue.

Tools & support

QR code: download the ACS app from the App Store

ⒶCS appScan to download for iPhone. Commission, configure and manage the network.
App Store · iOS

Model specifications

MSP-SRI/903P1/ACS

Performance

DetectionPIR · passive infrared
Range8 ft radius
Max mount13 ft
Coverage~690 ft² @ 13 ft
Hold timeApp-adjustable

Electrical

Input12–24 Vdc (host driver)
Power<0.5 W typical
WirelessMesh 1.1
Mesh nodesUp to 500
Connector1-pin AJ · 3.5 mm (1/8 in)

Installation

MountFixture, via 1-pin AJ
CommissionⒶCS app
PairingQR code
Host driverPowers sensor
Upgrade pathRe-flash to /BLS or /NLC

Construction

HousingWhite ABS
LensPIR · anti-glare
Operating temp14 °F to 122 °F
ColorWhite
ClassClass II
RatingIP20 · indoor

Compliance

ListingsUL · FCC · RoHS
DLC NLCListed · V5.2
Title 24§130.1 · §140.7
ASHRAE / IECC90.1 · C405.2
Warranty—

How it works

Plug in, scan, and the fixtures find each other.

ACS mesh: fixtures relay to each other; the app commissions the network.EACH NODE = A LUMINAIRE WITH A PLUG-IN SENSORUp to 500 nodes per mesh · 30–50 ft node spacing indoorsⒶCS appQR-code onboardingcommission · configure · scheduleⒶCS clouddaily energy + occupancymulti-site dashboard · rebate exportCLOUD UNREACHABLE → LOCAL CONTROL CONTINUES

Commission

QR code, no gateway

Pair from the ⒶCS app. The datasheet quotes under 30 minutes for a typical 10,000 ft² space.

Mesh

Up to 500 nodes

Self-healing multi-hop relay. 30–50 ft between nodes indoors.

Report

Energy + occupancy

Daily reporting to the ⒶCS cloud: multi-site dashboard and DLC NLC rebate export.

Resilient

Cloud drops, lights don't

Local occupancy, daylight and schedules continue unchanged. Reports queue and upload on reconnect.

Detection

8 ft radius. About 690 ft² at a 13 ft ceiling.

Detection pattern · top-downsensor centered

Top-down detection pattern, to scale: 8 ft radius, sensor centered.8 FTGRID 2 FT · OUTER RING 8 FT RADIUSINNER RING AS DRAWN ON DATASHEET, NOT DIMENSIONED

Coverage by mount heightdatasheet values

Coverage area by mount height, from the datasheet.0200400600FT²6.5 ft172 ft²10 ft388 ft²13 ft690 ft²16 ft— above 13 ft max mount

Range

8 ft

Radius, max range.

Max mount

13 ft

Ceiling height limit on the datasheet.

Node spacing

30–50 ft

Node to node, indoors.

Operating temp

14 to 122 °F

Class II, IP20 indoor.

Connection · 1-pin audio jack · 3.5 mm TRSfrom the datasheet wiring diagram

Audio-jack pinout: tip +V 12 to 24 Vdc, ring dim out 0 to 10 V, sleeve ground.Host fixtureLED driver12–24 Vdc out0–10 V dim in3.5 MM (1/8 IN) TRS PLUGSLEEVEGNDRINGDim out · 0–10 VTIP+V · 12–24 Vdc

Powered by the host fixture driver. Mismatched voltage damages the sensor.

Where it fits

Luminaires that take this sensor

Platforms

Same plug-in idea, three ways to run it.

Bi-Level

Standalone

Network
None · standalone
Set up with
IR remote, dials or DIP
Scale
One fixture
Input
10–15 Vdc · or line voltage
Reporting
—
DLC NLC
No · standalone

Nearest Bi-Level fixture sensor

MSP-HTI/08P1/BLS

by ⒶCS

Mesh + cloud

Network
Wireless mesh
Set up with
ⒶCS app · QR code
Scale
Up to 500 nodes
Input
12–24 Vdc · or line voltage
Reporting
Cloud dashboard · rebate export
DLC NLC
Listed · V5.2
You are here

by SILVAIR

Enterprise NLC

Network
Wireless mesh · SILVAIR
Set up with
SILVAIR app
Scale
500+ nodes
Input
12–24 Vdc
Reporting
BMS via open APIs
DLC NLC
Listed · V5.2

Same base, SILVAIR firmware

MSP-SRI/903P1/NLC

Order

Read the catalog number

MSP

PIR sensor

SRI

Indoor

903P1

Series 903 · 1-pin

/ACS

by ⒶCS

MSP-SRI/903P1/ACS

Ordering information

At a glance

Catalog numberMSP-SRI/903P1/ACS
UPC—
ListingUL · FCC · RoHS
DLCDLC NLC Listed · V5.2
Warranty—
BrandcontrⒶLS
Platformby ⒶCS
ManufacturerArchipelago Lighting Group

Not sure which platform?

Standalone, mesh or enterprise.

Start from the job: one fixture that dims itself, a building you want to see and report on, or a network that talks to the BMS.

Rebates

Check rebates before you specify.

Utility programs for lighting controls vary by service territory. The Rebate Center shows what applies to your site.