contrⒶLS · by ⒶCS · Occupancy sensor
MSP-SRI/903P1 /ACS
Fixture-integrated PIR sensor · 1-pin audio jack · wireless mesh
PIR occupancy sensor that plugs into the 1-pin audio-jack port on ⒶRCH luminaires, at the factory or in the field. Powered by the fixture's own driver. Joins an ⒶCS mesh of up to 500 nodes and commissions from the ⒶCS app by QR code: no gateway, no IT, no on-site Wi-Fi. If the cloud is unreachable, occupancy, daylight and schedules keep running.
Sensor
OCCUPIED
Light level
100%
Hold
—
Hold time and stand-by are set in the ⒶCS app; the bar is illustrative.
Downloads
Documents & tools
Documents
Some documents for this model are held for re-issue.
Tools & support
- Rebate CenterFind utility rebates for networked controls.→
- Find A RepLocal controls support and quotes.→
- Documentation LibraryEvery contrⒶLS document in one place.→

ⒶCS appScan to download for iPhone. Commission, configure and manage the network.
App Store · iOS
Model specifications
MSP-SRI/903P1/ACS
Performance
| Detection | PIR · passive infrared |
|---|---|
| Range | 8 ft radius |
| Max mount | 13 ft |
| Coverage | ~690 ft² @ 13 ft |
| Hold time | App-adjustable |
Electrical
| Input | 12–24 Vdc (host driver) |
|---|---|
| Power | <0.5 W typical |
| Wireless | Mesh 1.1 |
| Mesh nodes | Up to 500 |
| Connector | 1-pin AJ · 3.5 mm (1/8 in) |
Installation
| Mount | Fixture, via 1-pin AJ |
|---|---|
| Commission | ⒶCS app |
| Pairing | QR code |
| Host driver | Powers sensor |
| Upgrade path | Re-flash to /BLS or /NLC |
Construction
| Housing | White ABS |
|---|---|
| Lens | PIR · anti-glare |
| Operating temp | 14 °F to 122 °F |
| Color | White |
| Class | Class II |
| Rating | IP20 · indoor |
Compliance
| Listings | UL · FCC · RoHS |
|---|---|
| DLC NLC | Listed · V5.2 |
| Title 24 | §130.1 · §140.7 |
| ASHRAE / IECC | 90.1 · C405.2 |
| Warranty | — |
How it works
Plug in, scan, and the fixtures find each other.
Commission
QR code, no gateway
Pair from the ⒶCS app. The datasheet quotes under 30 minutes for a typical 10,000 ft² space.
Mesh
Up to 500 nodes
Self-healing multi-hop relay. 30–50 ft between nodes indoors.
Report
Energy + occupancy
Daily reporting to the ⒶCS cloud: multi-site dashboard and DLC NLC rebate export.
Resilient
Cloud drops, lights don't
Local occupancy, daylight and schedules continue unchanged. Reports queue and upload on reconnect.
Detection
8 ft radius. About 690 ft² at a 13 ft ceiling.
Detection pattern · top-downsensor centered
Coverage by mount heightdatasheet values
Range
8 ftRadius, max range.
Max mount
13 ftCeiling height limit on the datasheet.
Node spacing
30–50 ftNode to node, indoors.
Operating temp
14 to 122 °FClass II, IP20 indoor.
Connection · 1-pin audio jack · 3.5 mm TRSfrom the datasheet wiring diagram
Powered by the host fixture driver. Mismatched voltage damages the sensor.
Where it fits
Luminaires that take this sensor
Platforms
Same plug-in idea, three ways to run it.
Bi-Level
Standalone
- Network
- None · standalone
- Set up with
- IR remote, dials or DIP
- Scale
- One fixture
- Input
- 10–15 Vdc · or line voltage
- Reporting
- —
- DLC NLC
- No · standalone
Nearest Bi-Level fixture sensor
MSP-HTI/08P1/BLSby ⒶCS
Mesh + cloud
- Network
- Wireless mesh
- Set up with
- ⒶCS app · QR code
- Scale
- Up to 500 nodes
- Input
- 12–24 Vdc · or line voltage
- Reporting
- Cloud dashboard · rebate export
- DLC NLC
- Listed · V5.2
by SILVAIR
Enterprise NLC
- Network
- Wireless mesh · SILVAIR
- Set up with
- SILVAIR app
- Scale
- 500+ nodes
- Input
- 12–24 Vdc
- Reporting
- BMS via open APIs
- DLC NLC
- Listed · V5.2
Same base, SILVAIR firmware
MSP-SRI/903P1/NLCOrder
Read the catalog number
MSP
PIR sensor
SRI
Indoor
903P1
Series 903 · 1-pin
/ACS
by ⒶCS
Ordering information
At a glance
| Catalog number | MSP-SRI/903P1/ACS |
|---|---|
| UPC | — |
| Listing | UL · FCC · RoHS |
| DLC | DLC NLC Listed · V5.2 |
| Warranty | — |
| Brand | contrⒶLS |
| Platform | by ⒶCS |
| Manufacturer | Archipelago Lighting Group |
Not sure which platform?
Standalone, mesh or enterprise.
Start from the job: one fixture that dims itself, a building you want to see and report on, or a network that talks to the BMS.
Rebates
Check rebates before you specify.
Utility programs for lighting controls vary by service territory. The Rebate Center shows what applies to your site.